FFM-FR Series: Fouling Resistant Reverse Osmosis Membrane
FFM’s high-rejection RO membrane series is engineered specifically for brackish and saline water desalination, offering low operating pressure, exceptional salt rejection (>99.6%), strong fouling resistance, and stable performance.
Ideal for waters with salinity below 5,000 ppm—including well and surface water—these membranes serve drinking water systems, ionexchange pre-treatment, and industrial applications such as power plant boiler feedwater, high-salinity wastewater treatment, and beverage production.
| Model | Effective Membrane Area ft² (m²) |
Test Pressure psi (bar) |
Permeate Flow gpd (l/h) |
Stable Salt Rejection % |
|---|---|---|---|---|
| FFM2521HR | 14 (1.3) | 225 | 250 (1.32) | 99.6 |
| FFM2540HR | 30 (2.8) | 225 | 750 (2.8) | 99.6 |
| FFM4021HR | 36 (3.4) | 225 | 950 (3.6) | 99.6 |
| FFM4040HR | 85 (7.9) | 225 | 2200 (8.3) | 99.6 |
| FFM8040HR-375 | 375 (34.9) | 225 | 10000 (37.8) | 99.6 |
| FFM8040HR-400 | 400 (37.2) | 225 | 10500 (39.7) | 99.6 |
| FFM8040HR-440 | 440 (41) | 225 | 12500 (47.3) | 99.6 |
1. Test conditions: 500 mg/L (NaCl) aqueous solution; water temperature 25℃; recovery rate 50%;
2. The permeate flow rate of a single membrane element may vary within +/- 15%.
3. Membrane element performance parameters may change after product updates.
Operating and design parameters (operating limits):
| Maximum Operating Temperature | 113°F (45°C) |
| Maximum Operating Pressure | 600 psi (4.1 MPa) |
| Maximum Pressure Drop Per Element | 15 psi (0.1 MPa) |
| Maximum Pressure Drop Per Vessel | 50 psi (0.35 MPa) |
| pH Range, Continuous Operation | 2–11 |
| pH Range, Short Term Cleaning (30 min) | 1–13 |
| Maximum Feed Water SDI (15 mins) | 5 |
| Maximum Chlorine Concentration | < 0.1 mg/L |
Download
Download
FFM2521HR FFM2540HR FFM4021HR FFM4040HR FFM8040HR FFM8040HR-400 FFM8040HR-440