FFM Inc\'s ultra-low pressure reverse osmosis membrane is the lowest operating pressure in the existing reverse osmosis products. The conventional operating pressure range is 0.5-1.2mpa. It is also one of the reverse osmosis membrane elements with the lowest operating pressure in the world. FFM Inc\'s ultra-low pressure reverse osmosis membrane is mainly used for municipal tap water, groundwater and surface water with salt concentration less than 1000ppm, which is widely used in the preparation of purified water. FFM Inc\'s ultra-low pressure series reverse osmosis membrane has lower operating pressure and energy consumption, so the economic benefit is improved to a greater extent.
Product Specification:
Product Model | Membrane Area ft² (m²) | Test pressure psi (bar) | Water yield gpd (m³/d) | Desalination rate % |
FFM2521ELP | 14(1.3) | 100 (6.9) | 300 (1.13) | 99.0 |
FFM2540ELP | 27(2.5) | 100 (6.9) | 600 (2.27) | 99.0 |
FFM4021ELP | 36(3.34) | 100 (6.9) | 800 (3.04) | 99.0 |
FFM4040ELP | 85(7.9) | 100 (6.9) | 2400(7.9) | 99.0 |
FFM8040ELP-375 | 375(34.9) | 100 (6.9) | 9000(34.1) | 99.0 |
FFM8040ELP-400 | 400(37.2) | 100 (6.9) | 11000(41.6) | 99.0 |
FFM8040ELP-440 | 440(38.1) | 100 (6.9) | 12500(47.3) | 99.0 |
1. Test conditions: 500ppm NaCl solution, 25℃ water temperature, The recovery of 2521 / 4021 is 8%;The recovery of 2540/4040/8040is 15%.
2. The water yield of a single membrane element may vary within a range of + / - 20%.
3. After product renewal, the performance parameters of membrane components may change.
OPERATION PARAMETERS:
Maximum operating temperature:113 ℉(45℃)
Maximum operating pressure: 600 psi (41 bar)
Maximum pressure drop: 15 psi (1.0 bar)
PH range, continuous operation: 2-11
PH range, short term cleaning (30 minutes): 1-13
Maximum feed water SDI15: 5
Allowable free chlorine content:<0.1ppm
For special applications, please contact FFM Inc
Product Specification:
Product Model | Membrane Area ft² (m²) | Test pressure psi (bar) | Water yield gpd (m³/d) | Desalination rate % |
FFM2521ELP | 14(1.3) | 100 (6.9) | 300 (1.13) | 99.0 |
FFM2540ELP | 27(2.5) | 100 (6.9) | 600 (2.27) | 99.0 |
FFM4021ELP | 36(3.34) | 100 (6.9) | 800 (3.04) | 99.0 |
FFM4040ELP | 85(7.9) | 100 (6.9) | 2400(7.9) | 99.0 |
FFM8040ELP-375 | 375(34.9) | 100 (6.9) | 9000(34.1) | 99.0 |
FFM8040ELP-400 | 400(37.2) | 100 (6.9) | 11000(41.6) | 99.0 |
FFM8040ELP-440 | 440(38.1) | 100 (6.9) | 12500(47.3) | 99.0 |
1. Test conditions: 500ppm NaCl solution, 25℃ water temperature, The recovery of 2521 / 4021 is 8%;The recovery of 2540/4040/8040is 15%.
2. The water yield of a single membrane element may vary within a range of + / - 20%.
3. After product renewal, the performance parameters of membrane components may change.
OPERATION PARAMETERS:
Maximum operating temperature:113 ℉(45℃)
Maximum operating pressure: 600 psi (41 bar)
Maximum pressure drop: 15 psi (1.0 bar)
PH range, continuous operation: 2-11
PH range, short term cleaning (30 minutes): 1-13
Maximum feed water SDI15: 5
Allowable free chlorine content:<0.1ppm
For special applications, please contact FFM Inc